Views: 0 Author: Site Editor Publish Time: 2025-04-17 Origin: Site
Air Volume: 100000m³/h
Project Concentration: 1200mg/m³
The entire design and application of the project, project process: The designed air volume is 100,000 m³/h. It is a shipyard painting project. The total concentration of the project is relatively high at 1,200 mg/m³. A zeolite rotor +RTO is adopted, with an RTO air volume of 10,000 m³/h. High-concentration waste gas is introduced for treatment. The equipment selection for the project is based on the concentration and on-site working conditions analysis. Currently, the equipment is operating stably and the discharge at the outlet also meets the local discharge standards.