Project Operating Conditions: 10,000 m³/h
Exhaust Gas Concentration: 280mg/m³
Project operating conditions: The fixed-bed zeolite molecular sieve +CO process is adopted, with an air volume of 10,000 m³/h and an exhaust gas concentration of 280mg/m³. The selection of project equipment is based on the analysis of concentration and on-site working conditions. Currently, the equipment is operating stably and the discharge at the outlet also meets the local discharge standards.