Air Volume: 40000m³/h
Export Concentration: 23mg/m³
This project adopts the anti-sulfur catalyst developed by Xinjing Environment. It uses the activated carbon adsorption + catalytic combustion process, with a air volume of 40,000 m³/h and an exhaust gas concentration of 270mg/m³. Due to the presence of H2S in the exhaust gas, it can cause poisoning from conventional precious metal catalysts. Therefore, the anti-sulfur precious metal catalyst developed by our company was adopted. The discharge concentration at the outlet is approximately 23mg/m³, meeting the local discharge requirements and standards.